HELP REPAIR DOWNLOAD

H.E.I DISTRIBUTER MERCRUISER

 

STEP 1) NO SPARK?

     CHECK BATTERY VOLTAGE,  CONNECTIONS, AND CLAMP ON DISTRIBUTOR         

BASE.WITH KEY ON, CHECK FOR VOLTAGE ON COIL POS TERM, NO 12V CHECK          

 IGNITION SWITCH AND HARNESS.

 

STEP 2) STILL NO SPARK? BUT 12 V ON COIL +

     REMOVE THE WHITE / GREEN TRACER WHITE FROM DISTRIBUTOR, SPIN         ENGINE.

 

STEP 3) STILL NO SPARK?

     IF NO 12 V IN  RED LEAD COMING FROM MODULE, REPLACE MODULE.

 

STEP 4) STILL NO SPARK?

     WITH KEY IN RUN RAPIDLY TAP THR WHITE/GREEN WIRE ON IT'S TERMINAL

     WHILE CHECKING FOR SPARK FROM COIL CENTER TERMINAL HIGH VOLTAGE.

IF SPARK, REPLACE DISTRIBUTOR SENSOR

 

IF NO SPARK TRY NEW COIL

 

(800) 349-2628 ... (504) 888-2798 ... Fax (504) 888-2881
E-Mail to: (dmarine@rodnreel.com)

AfterMarket Home Page || Louisiana Fishing

AfterMarket Home Page: http//www.rodnreel.com/dmarine